( Brand: Siemens ), ( Manufacturer Part Number: 10285573 ), ( Model: ADVIA-2120I ), ( Country/region Of Manufacture: United States ), ( Type: Hematology Analyzer ), ( Country Of Origin: Ireland ), ( Intended Use/discipline: Biological Laboratory, Microbiological Laboratory )
The Siemens Advia 2120i Hematology Analyzer Extras Software is an advanced solution designed to enhance the capabilities of the Advia 2120i Hematology Analyzer. This software package offers additional functionality and features to provide laboratories with more comprehensive and accurate diagnostic information.
The Extras Software is specifically designed to expand the scope of the Advia 2120i's existing capabilities. It includes advanced algorithms to enable the analysis of more complex and rare blood disorders, such as reticulocyte counting, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular hemoglobin concentration (MCHC). These parameters are essential for the diagnosis and monitoring of various anemias, including microcytic, macroyctic, and normocytic anemias.
Moreover, the Extras Software includes a comprehensive suite of platelet functions, including platelet distribution width (PDW), mean platelet volume (MPV), and plateletcrit (PCT). These parameters are critical for the diagnosis and monitoring of various platelet disorders, such as thrombocytopenia, thrombocytosis, and platelet dysfunction.
Additionally, the software offers advanced features for the analysis of white blood cell (WBC) parameters, including absolute neutrophil count (ANC), absolute lymphocyte count (ALC), and differential analysis. These parameters are essential for the diagnosis and monitoring of various hematological disorders, including infections, leukemia, and lymphoma.
The Extras Software also includes a range of quality control and troubleshooting tools to ensure accurate and reliable results. These features include automated internal controls, external quality assurance, and troubleshooting guides.
Furthermore, the software offers seamless integration with laboratory information systems (LIS) and other diagnostic systems, enabling easy and efficient data transfer and analysis. This integration helps to streamline workflows and improve overall laboratory productivity.
In summary, the Siemens Advia 2120i Hematology Analyzer Extras Software is an advanced solution that expands the capabilities of the Advia 2120i Hematology Analyzer. It offers advanced algorithms for the analysis of complex and rare blood disorders, comprehensive platelet functions, and advanced WBC parameters. Additionally, it includes quality control and troubleshooting tools, as well as seamless integration with LIS and other diagnostic systems. This software is an essential tool for laboratories seeking to provide comprehensive and accurate diagnostic information for their patients.
The Siemens Advia 2120i is a versatile and advanced hematology analyzer that is widely used in clinical laboratories for the diagnosis and monitoring of various blood disorders. The extras software for this analyzer offers additional features and functionalities that can enhance the performance and capabilities of the instrument. In this response, we will discuss the pros and cons of buying a Siemens 10285573 Advia 2120i hematology analyzer extras software.
Pros:1. Improved Precision and Accuracy: The extras software offers advanced algorithms and methods for the analysis of blood samples, resulting in improved precision and accuracy of the results.
2. Enhanced Reporting: The software provides more comprehensive and detailed reporting, including the calculation of additional parameters and the generation of customized reports.
3. Increased Efficiency: The extras software can automate certain tasks, such as the calculation of platelet indices, reducing the workload of laboratory personnel and increasing efficiency.
4. Expanded Menu: The software expands the menu of the Advia 2120i, allowing for the analysis of additional tests and parameters, such as reticulocyte count, mean platelet volume, and platelet distribution width.
5. Compatibility with Other Systems: The software is compatible with other Siemens systems, enabling seamless integration and data transfer between instruments.
Cons:1. Cost: The extras software can be quite expensive, and laboratories may need to consider the cost-benefit analysis before making a purchase.
2. Training and Implementation: The software requires specialized training and implementation, which can be time-consuming and resource-intensive for laboratories.
3. Maintenance and Support: The software may require regular maintenance and updates, which can incur additional costs and require dedicated technical support.
Conclusion:The Siemens Advia 2120i hematology analyzer extras software offers several advantages, including improved precision and accuracy, enhanced reporting, increased efficiency, expanded menu, and compatibility with other systems. However, the software also comes with some disadvantages, such as cost, training and implementation, and maintenance and support. Laboratories need to carefully weigh the benefits and costs before making a purchase decision.
Recommendation:If your laboratory performs a high volume of hematology tests and requires advanced features and functionalities, the Siemens Advia 2120i hematology analyzer extras software may be a worthwhile investment. However, if your laboratory has limited resources or only requires basic hematology testing, the cost and implementation effort of the software may outweigh the benefits. It is recommended that laboratories carefully evaluate their testing needs and budget before making a purchase decision.
Clean and in good cosmetic condition. Expedited Shipping: processing and delivery are available on most items but due to the nature of equipment, it cannot be guaranteed. Advanced Indices: Direct measurement of untraceable hemoglobin concentration CHCM and volume on a cell-by-cell basis for Rb's, Platelet's, Ridiculousness. Software Expansion: Fully compatible with the Siemens Data Management System and supports bidirectional LIS host querying.
Applications: Engineered for highly specialized diagnostic testing across clinical and research fields: Routine Clinical Diagnostics: High-speed complete blood counts precise flagging blasts immature granulates. Inspected By: Its unique dual-differential technology utilizes a secondary total white cell count as an internal quality control check to monitor sample integrity, significantly reducing manual slide-review rates. DO NOT discard the packaging.
Declared value is accurately stated and the package insured at selling price. Body Fluid Assay: Validated automated testing parameters for fluid CSF to enumerate RBC and Total Nucleated Cell TNC counts. The system was regularly maintained. Some States do not allow the exclusion or limitation of incidental consequential damages, so above may apply to you.
It is being sold as described and not complete. Model: Advia 2120I. Likely needs new batteries. If you do receive the package, submit clear images of packaging/box and damaged item from multiple angles.
All components powered up. See full for details. Auto waste assembly is in good condition, though the collar missing for mode selector knob on this unit. Optional Modules: Supports the optional ADVIA Auto slide module for integrated smear preparation.
Notes: Good condition. Without the HDD, computer booted only to bios but hardware diagnostics were good. Anemia Differentiation: Utilizing reticulated cellular hemoglobin content Che and size metrics to early-diagnose iron deficiency monitor therapeutic response. We conduct an honest business, with a long eye to our brand, and will always work make your experience us good one.
Not fully complete. Electrical Re: 120V AC 50/60Hz. Item ID: 39020. UPS system powered.
Value-Add: Features the integrated Unified Fluids Circuit UFC block which minimizes internal tubing, drastically reducing fluid friction, reagent consumption, and routine valve maintenance. Condition: Used. Save packaging for carrier claim. Brand: Siemens.