( Brand: Jobin Yvan Horiba ), ( Manufacturer Part Number: 350515 ), ( Model: FLUROMAX-3 )
The Jobin Yvon HORIBA Fluoromax 350515 monochromator is a versatile and high-performance optical instrument designed for fluorescence measurements in various fields, including analytical chemistry, material science, and biology. This motorized monochromator is a part of the Fluoromax series, which is known for its exceptional stability, ease of use, and high-quality optical components.
The core feature of the 350515 monochromator is its motorized design, which allows for precise and accurate wavelength selection. The monochromator comes with a high-resolution grating that offers a spectral bandwidth as low as 0.5 nm and a wavelength range from 190 to 1150 nm. The motorized wavelength tuning enables fast and reliable wavelength scans, making it an ideal instrument for fluorescence spectroscopy applications.
The monochromator is constructed with high-quality optical components, such as high transmission mirrors and a low-scatter optical design. These features ensure that the instrument delivers high-quality and accurate fluorescence measurements. Additionally, the monochromator is equipped with a high-sensitivity photomultiplier tube detector, which provides excellent detection limits and high signal-to-noise ratios.
The 350515 monochromator also includes several advanced features to enhance its performance and ease of use. For example, it features an automatic wavelength calibration function, which ensures accurate wavelength measurements by automatically correcting for any wavelength drift or misalignment. It also offers a built-in data processing system, which includes various data analysis tools and can be controlled via a user-friendly software interface.
The monochromator is designed with a compact and robust construction, making it suitable for use in various laboratory environments. It is also easy to integrate with other laboratory instruments, such as liquid chromatography or mass spectrometry systems, for hyphenated techniques. Overall, the Jobin Yvon HORIBA Fluoromax 350515 motorized monochromator is a powerful and versatile instrument for fluorescence measurements, offering excellent performance, ease of use, and high-quality optical components.
The Jobin Yvon Horiba 350515 Fluromax monochromator is a high-performance instrument used for fluorescence measurements and analysis. Here are some pros and cons that may help you in deciding whether to purchase this monochromator:
Pros:1. High Resolution: The monochromator provides a high resolution of up to 0.2 nm, enabling accurate and precise fluorescence measurements.
2. Motorized Monochromator: The motorized design allows for easy and automated wavelength scans, making it ideal for applications requiring repeated measurements.
3. Wide Wavelength Range: The monochromator covers a wide wavelength range of 190 to 1100 nm, making it suitable for various fluorescence analysis applications.
4. High Stability: The instrument offers high stability with a long-term wavelength drift of less than 0.1 nm per hour, ensuring reliable and accurate results.
5. Excellent Optical Throughput: The monochromator has a high optical throughput, allowing for sensitive and low-level fluorescence measurements.
Cons:1. High Cost: The Jobin Yvon Horiba 350515 Fluromax monochromator is a high-end instrument with a significant investment required, making it less accessible to smaller research labs and educational institutions.
2. Complex Setup: The instrument may require a complex setup process, including proper alignment and calibration, which can be time-consuming and may require specialized knowledge.
3. Limited Sample Size: The monochromator has a limited sample size capacity, which may not be suitable for applications requiring the analysis of large sample volumes.
4. Power Consumption: The monochromator has a relatively high power consumption, which can result in increased operational costs.
Conclusion:The Jobin Yvon Horiba 350515 Fluromax monochromator is a high-performance instrument with excellent features, including high resolution, motorized design, wide wavelength range, high stability, and excellent optical throughput. However, its high cost, complex setup, limited sample size capacity, and high power consumption may make it less accessible to smaller research labs and educational institutions.
Recommendation:If you require high-accuracy and high-precision fluorescence measurements in your research or industrial application, and you have the budget and resources to invest in a high-end instrument, then the Jobin Yvon Horiba 350515 Fluromax monochromator may be an excellent choice for you. However, if you have a limited budget or sample size requirements, or if you prefer a more compact and less complex instrument, you may want to consider alternative solutions, such as a benchtop monochromator or a filter-based fluorescence spectrophotometer.
Model number: Fluromax-3, Part 350515, Motorized monochromator. Sale is for one 1 motorized monochromator. See photos and read for details about this part. Horiba Jobin Yvon - Motorized Monochromator 350515.
Removed from surplus local university. On part or box. This includes apartments, townhouses, shared industrial buildings, strip malls, etc. No other parts included in this sale.
See photos for details. Surplus part may have stickers, inventory label, dust, dirt etc.