( Brand: Corning ), ( Manufacturer Part Number: 352360 ), ( Model: CORNING FALCON 352360 ), ( Part Type: Flow Cell ), ( Country/region Of Manufacture: United States )
The Corning Falcon Cell Strainers 70 m, product number 352360, are a essential tool for researchers and laboratory professionals working with suspension cell cultures, particularly those involved in flow cytometry applications. These cell strainers are designed to effectively remove debris and larger cells from cell suspensions, ensuring that only the desired cells pass through for further analysis.
The cell strainers are manufactured from polycarbonate material, which provides strength and durability while maintaining excellent clarity. The strainer inserts feature a large 70 m pore size, making them suitable for most flow cytometry applications. The inserts are stacked within a sturdy, reusable polypropylene conical filter housing. This design not only allows for easy filtration of cell suspensions, but also enables the re-use of the housing for multiple experiments.
The cell strainers are compatible with a wide range of volumes, making them versatile for various lab applications. The conical filter housing can accommodate volumes as low as 10 mL and as high as 50 mL. The cell strainers can be easily assembled and disassembled for cleaning and sterilization.
The Falcon Cell Strainers are also designed to minimize shear forces on the cells during filtration, preserving cell viability and maintaining cell integrity. The smooth, round pores of the strainers reduce the risk of cell damage, ensuring that the cells are in optimal condition for downstream applications such as flow cytometry, cell sorting, or other assays.
In summary, the Corning Falcon Cell Strainers 70 m (product number 352360) are an indispensable tool for researchers and laboratory professionals working with suspension cell cultures and flow cytometry applications. Their robust design, large pore size, and compatibility with various volumes make them a versatile and reliable choice for filtering cell suspensions while minimizing cell damage and maintaining cell viability.
The Corning Falcon Cell Strainers 70 m, Model No. 352360, are filter devices commonly used in laboratories for cell separation and filtration during various experimental procedures. Here are some pros and cons of buying this product:
Pros:1. High-quality and durable: Corning is a well-known and reputable brand in the scientific community. These cell strainers are made of high-density polyethylene (HDPE) material, which is known for its durability and resistance to chemicals.
2. Large strainer area: The 70 m pore size is suitable for most cell separation applications. The large strainer area (3.4 cm ) allows for efficient filtration of large volumes of cell suspensions.
3. Easy to use: The cell strainers are stacked within a conical filtration unit, making the filtration process simple and convenient. The flow cytometry design ensures that cells pass through the filter without clogging, allowing for continuous filtration.
4. Versatile: These cell strainers can be used in various applications, including cell culture, flow cytometry, and microbiology. They are suitable for a wide range of cell types and sizes.
5. Cost-effective: The cell strainers are available in different sizes and quantities, making it a cost-effective solution for laboratories with varying filtration requirements.
Cons:1. Limited to small samples: Although the large strainer area allows for efficient filtration of large volumes, it may not be suitable for filtering large quantities of cells in a single batch. For larger sample sizes, multiple filters or larger filter units may be required.
2. Requires additional equipment: The cell strainers require a conical filtration unit or a vacuum manifold for proper use. These additional pieces of equipment may add to the overall cost and complexity of the filtration setup.
3. Not suitable for all applications: The 70 m pore size may not be suitable for all cell separation applications. For example, if you need to separate cells that are much smaller or much larger than the specified pore size, you may need to use different filter devices.
In conclusion, the Corning Falcon Cell Strainers 70 m are a reliable and efficient solution for cell separation and filtration applications. Their high-quality, durability, and versatility make them a valuable addition to any laboratory. However, their limited capacity for large sample sizes and the requirement for additional equipment may be disadvantages for some users. Ultimately, the decision to purchase the Corning Falcon Cell Strainers 352360 depends on the specific filtration requirements of your laboratory. If your laboratory routinely deals with moderate to large sample sizes and you require high-quality and efficient cell separation, then these cell strainers are an excellent investment.
Unused stock from a shutdown laboratory Open box with 46 individually sealed units.