( Brand: Becton ), ( Manufacturer Part Number: 4345027 )
Introducing the Becton Dickinson (BD) Crystal Microbiology Media, product number 4345027, a premium choice for microbiology laboratories seeking accurate and reliable results for the detection and identification of microorganisms. This media is designed specifically for the crystal method of microbiological testing, a technique widely used for the detection of gram-positive bacteria.
The BD Crystal Microbiology Media comes in the form of a ready-to-use, pre-poured, and pre-labeled plate, ensuring ease of use and convenience for laboratories. Each plate contains a clear, colorless medium that allows for clear and distinct crystal formation upon the growth of microorganisms. This feature facilitates easy and rapid identification of microbial growth, saving time and resources.
The media's formulation includes a selective and enriched nutrient base that supports the growth of a broad range of gram-positive bacteria, including Streptococcus, Staphylococcus, and Enterococcus species. The media's pH is carefully controlled to create optimal conditions for microbial growth, ensuring consistent and accurate results.
The BD Crystal Microbiology Media is manufactured using high-quality raw materials and undergoes rigorous quality control testing to ensure product purity and consistency. The media is sterilized using gamma irradiation, ensuring the elimination of any potential contaminants and maintaining sterility throughout the shelf life of the product.
This media is stable and can be stored at room temperature for up to 12 months from the date of manufacture. Proper storage conditions, including protection from light and extreme temperatures, are essential to maintaining the media's quality and ensuring optimal results.
In summary, the Becton Dickinson (BD) Crystal Microbiology Media, product number 4345027, is a high-quality and reliable choice for microbiology laboratories seeking accurate and consistent results for the detection and identification of gram-positive bacteria using the crystal method. The media's ease of use, broad range of microbial detection capabilities, and high-quality manufacturing make it an essential tool for any microbiology laboratory.
The Becton Dickinson (BD) 4345027 Dickinson Crystal Microbiology Media is a popular choice for cultivating microorganisms in laboratories. This media comes in the form of pre-reduced, sterile borosilicate glass beads coated with a nutrient agar. Here are some pros and cons of using this media:
Pros:1. Pre-reduced: The media is pre-reduced, which means that it has been treated to prevent oxidation. This is particularly important for the cultivation of anaerobic microorganisms.
2. Sterile: The media is sterile, which ensures that there are no contaminants that could interfere with the growth of microorganisms.
3. Versatile: The media can be used for a variety of microbiological applications, including the cultivation of bacteria, fungi, and mycobacteria.
4. Easy to use: The media comes in the form of beads, which makes it easier to distribute evenly in plates and tubes.
5. Long shelf life: The media has a long shelf life, which makes it a cost-effective option for laboratories.
Cons:1. Cost: The media can be more expensive than other types of media, due to the use of borosilicate glass beads.
2. Fragile: The glass beads can be fragile and may break if not handled carefully.
3. Requires special equipment: The media requires specialized equipment, such as anaerobic jars or tubes, to maintain the desired environmental conditions.
4. Limited growth area: Each bead only provides a limited area for the growth of microorganisms, which may be a limitation for studies that require large cultures.
In conclusion, the Becton Dickinson 4345027 Dickinson Crystal Microbiology Media offers several advantages, including its pre-reduced and sterile properties, versatility, and long shelf life. However, it also has some disadvantages, such as its cost, fragility, and requirement for specialized equipment. Based on these considerations, this media may be a good choice for laboratories that require the cultivation of anaerobic microorganisms or have a need for a versatile and long-lasting media. However, for laboratories with limited budgets or large culture requirements, other types of media may be more cost-effective.
Recommendation: The Becton Dickinson 4345027 Dickinson Crystal Microbiology Media is a high-quality media suitable for laboratories that require the cultivation of anaerobic microorganisms or have a need for a versatile and long-lasting media. However, it may not be the most cost-effective option for laboratories with large culture requirements or limited budgets. Researchers are encouraged to evaluate their specific needs and consider the costs and benefits of this media before making a purchase.
Simplified inoculation: The system requires only a single inoculation step. The Becton Dickinson BBL Crystal light box is a component of the microbial identification system that features an automated, self-contained, and user-friendly process. It comes exactly as shown. Automatic filling: The devices wells fill automatically by rocking the base.
The system includes an auto reader that analyzes the panels and displays results on-screen, identifying organism providing epidemiological information. Self-contained design: The panel is a closed system, which safe and easy to handle. Up for sale is a Becton Dickinson BBL Crystal Microbial ID System. Operating temperature: 18 3018 30 C.
Expedited shipping is available if needed. Safety and convenience: The lid snaps on for safety ease of handling. Please reach out for any reason. Technical specifications Electrical requirements: The auto reader operates on 100 240 VAC, single-phase power, with an input current of 0.370.37 0.37 A and a frequency 50/6050 / 60 50/60 Hz.
No reagent addition: The panel design eliminates the need for manual addition and oil overlays. On-screen results: The systems software displays the identified organism, epidemiological information, and other relevant data on a lab computer. Key features include an easy, one-step inoculation, a safe closed-system design, elimination of manual reagent addition, and system that works with pre-made, ready-to-use inoculate broth. This unit ships via postage.
System features Automated analysis: The BBL Crystal system uses an auto reader to analyze the panels after incubation. It was acquired from a lab and has been tested. Its in excellent unused condition, as shown the pics. Organisms are suspended in Crystal Broth, and the mixture is poured directly into device.
Operating humidity: 15 90%15 90 % 90% relative humidity non-condensing.