( Brand: Becton Dickinson ), ( Manufacturer Part Number: 656035 ), ( Part Type: Flow )
The BD Accuri C6 Flow Cytometer by Becton Dickinson is a versatile and high-performing instrument designed for researchers and clinical laboratories seeking accurate and reliable flow cytometry data. This particular system comes with two lasers, one emitting at 488 nm and the other at 552 nm, powered by Coherent OBIS solid-state lasers.
The 488 nm laser provides excellent excitation for fluorochromes commonly used in flow cytometry, such as FITC (Fluorescein Isothiocyanate), PE (Phycoerythrin), and PerCP (Peridinin-Chlorophyll-Complex). These fluorochromes emit green and red fluorescence, respectively, which are typically used to detect various cellular markers in immunology, cell cycle analysis, and apoptosis studies.
The 552 nm laser, on the other hand, is ideal for excitation of red-shifted fluorochromes like APC (Allophycocyanin) and APC-Cy7. These fluorochromes have emission peaks in the red spectrum, allowing for the detection of multiple parameters in a single experiment. The use of two lasers ensures higher sensitivity and accuracy in the detection of various cell populations, even in complex samples.
The BD Accuri C6 Flow Cytometer features a user-friendly interface, which includes the Accuri C6 Software. This software enables users to easily acquire, analyze, and interpret data in real-time. The system also supports up to 10 colors and 22 parameters, allowing for comprehensive characterization of cell populations in various research applications.
The instrument's compact design makes it an excellent choice for laboratories with limited space, while its robust construction ensures durability and reliability. The BD Accuri C6 Flow Cytometer is a powerful and flexible tool for researchers and clinicians seeking high-quality flow cytometry data, making it an essential addition to any laboratory working in the fields of immunology, oncology, stem cell research, and more.
The BD Accuri C6 Flow Cytometer from Becton Dickinson is a compact, benchtop flow cytometer designed for research use. This instrument uses 552 nm and 488 nm lasers for excitation and offers up to 12 colors of detection. In this response, we will discuss the pros and cons of buying a BD Accuri C6 Flow Cytometer.
Pros:1. Compact and Benchtop Design: The BD Accuri C6 Flow Cytometer has a small footprint, making it an excellent choice for laboratories with limited space. Its benchtop design allows for easy access and operation.
2. High-Performance: This instrument offers high-performance flow cytometry capabilities, including up to 20,000 events per second (EPS) throughput and advanced FSC/SSC gating.
3. User-Friendly: The BD Accuri C6 Flow Cytometer is known for its user-friendly design. It includes the Accuri C6 Software, which offers intuitive data analysis tools and is easy to navigate.
4. Cost-Effective: Compared to larger, more expensive flow cytometers, the BD Accuri C6 Flow Cytometer is a cost-effective solution for research laboratories.
5. Versatile: The BD Accuri C6 Flow Cytometer is suitable for a wide range of applications, including cell sorting, immunophenotyping, and apoptosis analysis.
Cons:1. Limited Sample Volume: The BD Accuri C6 Flow Cytometer has a limited sample volume, which may not be suitable for large sample analyses.
2. Limited Laser Lines: While the 552 nm and 488 nm lasers offer a good range of detection, researchers may require additional laser lines for more complex experiments.
3. Limited Integration with Other Systems: The BD Accuri C6 Flow Cytometer may not integrate as seamlessly with other laboratory systems as more expensive flow cytometers.
4. Maintenance: Like all flow cytometers, the BD Accuri C6 Flow Cytometer requires regular maintenance to ensure optimal performance.
In conclusion, the BD Accuri C6 Flow Cytometer is a cost-effective, user-friendly, and high-performance flow cytometer suitable for research laboratories with limited space and budget. Its compact design, versatility, and easy-to-use software make it an excellent choice for researchers requiring a benchtop flow cytometer for a wide range of applications. However, its limited sample volume, laser lines, and integration capabilities may be limitations for some researchers. Ultimately, the decision to purchase the BD Accuri C6 Flow Cytometer depends on the specific needs and resources of the research laboratory.
Recommendation:If you are a researcher with limited space and budget, and your research requirements include a wide range of flow cytometry applications, the BD Accuri C6 Flow Cytometer is an excellent choice. Its compact design, user-friendly software, and high-performance capabilities make it a valuable addition to any research laboratory. However, if you require a larger sample volume, more laser lines, or greater system integration, you may need to consider more expensive flow cytometers. Before making a final decision, it is essential to evaluate the specific needs and resources of your research laboratory to determine if the BD Accuri C6 Flow Cytometer is the right choice for you.
On powering off blue led again flashes while it does its shutdown procedure, then the system turns. RUO Special Order System with 552nm and 488nm Coherent OBIS lasers. The waste bottle should be replaced as it is cracked at the top. Used in good condition as shown the photographs.
Powers and you can hear the pumps operating. As I cannot verify operation beyond powering on as described, this is sold for parts. Item#525007LN. No software so no further testing done.
Includes the fluids harness with bottles and lids. On power up, the front traffic light turns on then off and blue led flashes during startup procedures to solid.