( Brand: Becton Dickinson ), ( Manufacturer Part Number: 657338 ), ( Part Type: Flow Laser Analyzer ), ( Unit Type: Unit ), ( Country Of Origin: United States ), ( California Prop 65 Warning: This Product Contains Chemicals Known To The State Of California To Cause Cancer And Reproductive Harm. ), ( Intended Use/discipline: Hematology, Immunology, Flow Cytometry, Cell Analysis, Clinical Laboratory, Biotechnology Life Sciences, Pharmaceutical Research, Research Development )
The BD FACSCanto II Flow Cytometer from Becton, Dickinson and Company is a versatile and powerful multicolor analyzer designed for high-performance research and clinical applications. This flow cytometer is engineered with the latest technology to deliver accurate and reliable results, making it an essential tool for investigators in various fields such as immunology, stem cell research, and gene expression analysis.
At the heart of this instrument is a 2016 laser configuration, which includes three lasers that emit blue (488 nm), red (633 nm), and violet (405 nm) wavelengths. The use of multiple lasers enables the analysis of up to 16 different parameters using fluorescence detection, allowing for complex experimental designs and comprehensive data acquisition.
The BD FACSCanto II features a robust flow cell design, which ensures stable flow conditions and minimizes sample loss. This instrument is capable of processing up to 30,000 events per second, making it an excellent choice for high-throughput applications. Additionally, the advanced autogating and doublet discrimination algorithms allow for accurate separation and identification of events, resulting in cleaner data and reduced background noise.
Moreover, the BD FACSCanto II comes equipped with BD FACSDiva software, a powerful and user-friendly analysis tool that enables users to easily set up and run experiments, analyze data, and generate high-quality graphs and reports. The software offers various features, such as parameter gating, data compensation, and integrated quality control checks, which ensure accurate and reproducible results.
In summary, the BD FACSCanto II Flow Cytometer with a 2016 laser configuration is a cutting-edge multicolor analyzer that offers high-performance and versatility for research and clinical applications. Its advanced laser configuration, robust flow cell design, and user-friendly software make it an indispensable tool for investigators in various fields, enabling them to generate accurate and reliable data for their research projects.
The BD FACSCanto II flow cytometer is a popular choice for researchers and laboratories due to its high performance, versatility, and ease of use. This particular model, BD 657338, comes with the 2016 multicolor analyzer and laser configuration, which offers enhanced capabilities for analyzing complex samples. In this analysis, we will discuss the pros and cons of purchasing this instrument.
Pros:1. High-Performance Detection: The BD FACSCanto II flow cytometer is known for its exceptional sensitivity and accuracy. The laser configuration with the 2016 multicolor analyzer allows for the detection of up to 16 different parameters simultaneously.
2. User-Friendly Interface: The instrument comes with a user-friendly interface, making it easy for users to set up experiments, analyze data, and troubleshoot issues.
3. Versatility: The BD FACSCanto II flow cytometer can be used for a wide range of applications, including immunophenotyping, apoptosis analysis, and cell cycle analysis.
4. Reliable and Durable: The instrument is built with high-quality components and is known for its reliability and durability.
5. Integration with Other Software: The BD FACSCanto II flow cytometer can be easily integrated with other software, such as BD FACSDiva, for data analysis and visualization.
Cons:1. High Cost: The BD FACSCanto II flow cytometer with the 2016 multicolor analyzer and laser configuration is a significant investment.
2. Complex Setup: Although the instrument is user-friendly, setting it up for the first time can be a complex process, requiring some technical expertise.
3. Limited Sample Size: The instrument can only analyze a limited number of samples at a time, which may be a concern for high-throughput applications.
Conclusion:The BD FACSCanto II flow cytometer with the 2016 multicolor analyzer and laser configuration is a high-performance instrument suited for researchers and laboratories requiring advanced analysis capabilities. Its user-friendly interface, versatility, and reliability make it an excellent choice for a wide range of applications. However, the high cost and complex setup may be a deterrent for some users.
Recommendation:If your research or laboratory requires advanced flow cytometry analysis capabilities and you have the budget for it, the BD FACSCanto II flow cytometer with the 2016 multicolor analyzer and laser configuration is an excellent investment. For those with limited budgets or smaller sample sizes, other flow cytometry instruments may be more suitable. It is recommended to consult with a flow cytometry expert or supplier to determine the best fit for your specific research or laboratory needs.
Quick Details, Brand BD Bio sciences, model FACSCanto 3 Lasers, Condition Used, Includes Unit with HTS box and Fluid, Cart as shown in Photos. BD FACSCanto Flow Cytometer 3 Laser Configuration 2016 Multicolor Analyzer The is a multicolor cell analysis system configured with 3-laser setup, enabling advanced fluorescence detection and enhanced multi-parameter. and multicolor cell analysis. 01 Laboratory Research Applications.
This 2016 system is designed to deliver reliable and reproducible results across a wide range of flow cytometry applications. Biotechnology and academic research laboratories.