( Brand: Binder ), ( Manufacturer Part Number: 9040-0082 ), ( Model: C150-UL ), ( Part Type: Display Control Sensor ), ( Country/region Of Manufacture: Germany ), ( Intended Use/discipline: Biological Laboratory, Medical Laboratory, Microbiological Laboratory )
The Binder 9040-0082 150-ul CO2 Incubator with FPI-Sensor Display and Control is a high-performance, versatile solution for maintaining optimal growing conditions for cells, tissue cultures, and microorganisms in laboratory settings. This incubator is designed to provide precise control over temperature, CO2 levels, and humidity, ensuring the best possible environment for your biological samples.
The heart of this incubator is the FPI-Sensor Display and Control system. This advanced technology enables real-time monitoring and regulation of the incubator's conditions. The bright, easy-to-read display provides clear information about temperature, CO2 levels, and humidity, while the intuitive controls make it simple to adjust settings as needed. The FPI-Sensor system also offers an alarm function, alerting users when conditions fall outside of the preset ranges.
The Binder 9040-0082 150-ul CO2 Incubator boasts a generous working volume of 150 liters, providing ample space for a large number of samples. Its robust design and construction ensure stability and durability, while its smooth, quiet operation minimizes disruptions to the environment.
This incubator is specifically designed for applications that require precise control over CO2 levels, making it an ideal choice for cell lines, tissue cultures, and microorganisms that are sensitive to CO2 concentrations. The incubator's CO2 control system maintains a stable environment by continuously monitoring and adjusting CO2 levels, ensuring that your samples receive the optimal conditions they need to thrive.
Additional features of the Binder 9040-0082 150-ul CO2 Incubator include an adjustable airflow rate, which allows users to customize the flow of air throughout the incubator, and an optional heating jacket, which can be added for applications that require additional temperature control.
In summary, the Binder 9040-0082 150-ul CO2 Incubator with FPI-Sensor Display and Control is a high-performance, versatile solution for maintaining optimal growing conditions for cells, tissue cultures, and microorganisms in laboratory settings. Its advanced FPI-Sensor Display and Control system, generous working volume, and precise CO2 control make it an essential tool for any researcher or lab technician seeking to optimize their biological research.
a. FPI-Sensor Technology: The incubator is equipped with a Front Panel Indicator (FPI) sensor that allows for real-time monitoring of CO2 levels and temperature, ensuring optimal growing conditions for cells or microorganisms.
b. Large Capacity: With a working volume of 150L, this incubator offers ample space for large-scale experiments or multiple experiments at once.
c. High Precision: The Binder 9040-0082 maintains a high degree of temperature and CO2 precision, with a temperature range of 4 to 45 C and a CO2 range of 1 to 15%.
d. User-Friendly: The incubator features an easy-to-use control panel and intuitive touchscreen display, making it simple for users to adjust and monitor conditions as needed.
e. Energy Efficient: The Binder 9040-0082 is designed to be energy efficient, reducing the cost of long-term operation.
2. Cons:a. Price: The Binder 9040-0082 is a high-end incubator, and its price point may be a deterrent for some researchers or laboratories with limited budgets.
b. Size: The large capacity of the incubator necessitates a substantial amount of bench or floor space.
c. Complexity: Due to its advanced features, the Binder 9040-0082 may require some additional setup and maintenance time compared to simpler incubators.
3. Conclusion:The Binder 9040-0082 150-ul CO2 Incubator with FPI-Sensor Display and Control (150L) offers numerous advantages for researchers and laboratories, including real-time monitoring of CO2 levels and temperature, large capacity, high precision, user-friendliness, and energy efficiency. However, its significant price tag and size may pose challenges for some users. Ultimately, the decision to purchase this incubator depends on the specific needs, budget, and available space of the research facility.
4. Recommendation:If your laboratory requires a large-scale incubator with advanced features for monitoring and controlling CO2 levels and temperature, the Binder 9040-0082 150-ul CO2 Incubator with FPI-Sensor Display and Control (150L) is an excellent choice. However, if budget or space constraints are a concern, consider researching alternative, more affordable models with similar capabilities or smaller capacities. Always evaluate the unique requirements of your research project before making a purchase.
Mark them when damaged. Condition: Use din Clean, Excellent working condition. Specifications. Secure gas cylinders during storage and use against falling chaining.
Establishing the connection to incubator. The valve of the gas cylinder always must be closed before screwing on or unscrewing hose. These coloration's are harmless indwell in no way impair the function or quality of unit. Make sure that the water pan has firm contact with inner chamber bottom and rests tightly on it.
Setting accuracy. The inner chamber is deep-drawn from one piece, polished suitable for and has no welds or inaccessible corners. Number of doors. IP system of protection acct.
The perforated shelves are made of stainless steel. Protect gas cylinders against fire, Interior Dimensions. This is achieved by entering the altitude of site above sea.
With leak spray or diluted soap solution. Temperature Data. To remove the connection, pull hose nozzle off quick acting closure socket. You can insert a maximum of six shelves.
For evacuation, remove the water pan. The distances between the molecules are consequently pressure-dependent. After connecting the gas cylinder, check all connections for leaks Pollution degree acct.
Depth plus power supply connection and gas. The Binder C150-UL 9040-0082, Series C 150 incubator is suitable for the cultivation of mammal cells under typical conditions of approx. Humidity Data. The gas enters the chamber via a fine filter aseptic filter with high filtration efficiency that also filters smallest particles.
Do not store together with flammable liquids. Then put the water pan in positioning frame. Interior volume. Hold the shelf straight and then insert it so will go smoothly inside unit.
Temperature in C. Size of shelf, width x depth. Ste-mart CAT #: STEM-CC-2181-LGZ for Binder C150-UL CO2 Incubator. Transport gas cylinders with a cylinder cart, do not carry,roll, or throw them.
Place the positioning frame on two marks at bottom of the inner chamber. Permitted shelf loads. The door must be closed while the unit is operating normally in order to ensure stable climatic conditions in inner chamber. It is colorless and almost odorless therefore practically imperceptible.
Temperature fluctuation. Plug the hose nozzle into corresponding quick acting closure socket located at rear of unit. Number of shelves, series / max. Use a pressure reducer and make sure to avoid any excessive outlet when connecting the gas hose incubator.
Number of inner glass doors. The water pan permits high humidity without condensation anther inner walls of the incubator. Open the gas cylinder valve slowly to avoid pressure surges. Secure the gas cylinders against falling and other mechanical damage.
All corners and edges are also completely coated. The inner surfaces are smooth and therefore easy to clean. This creates optimum growth conditions for cultures. Wall clearance rear.
Empty the water pan before moving incubator. Do not open gas cylinders by force. In case of the contents spilling, immediately shut down the incubator and dry it carefully and completely. The inner chamber, the pre-heating chamber and inside of the doors are all made of stainless steel material no.
Nominal power. Depth plus door handle, I-triangle. Binder C 150-UL 9040-0082 CO2 Incubator with FPI-Sensor System and Display Controller RP1, Left Door Hinges, 115V, Comes 2 Shelves Water Pan in The Positioning Frame 150 UL. height incl.
Connecting the gas hose to unit rear. When operating the chamber at high temperatures sterilization, impact of oxygen in air may cause discoloration of metallic surfaces yellowish-browner blue by natural oxidation processes. Decreasing supply pressure results in longer recovery times. Weight empty.
Wall clearance side. Return gas cylinders with the valve closed. Exterior Dimensions. Connection to the unit for hose with internal diameter.
37 C / 98.6. Humidity range. The hinges and the self inner glass door are glued from outside to aid cleaning of inner chamber. Always close the valve even with apparently empty cylinders;screw on cap when not in use.