1. Other Lab Equipment For Sale
  2. sku: 16482458095276622
  3. BRUKER H9877

BRUKER H9877 Acs Sample Changer Carousel Magazine Nmr 120 400US Spectroscopy

400us Bruker H9877 B-acs 120 Sample Changer Carousel Magazine Nmr Spectroscopy

( Brand: Bruker ), ( Manufacturer Part Number: H9877 ), ( Part Type: Ac Changer ), ( Country/region Of Manufacture: Germany ), ( Intended Use/discipline: Biological Laboratory, Medical Laboratory, Microbiological Laboratory )

Review BRUKER B acs 120 Sample Changer Carousel Magazine Nmr Spectroscopy

The Bruker H9877 B-ACS 120 Sample Changer is an essential accessory for high-performance NMR (Nuclear Magnetic Resonance) spectroscopy experiments, designed to accommodate up to 120 samples in a 400US carousel magazine. This sample changer is engineered to seamlessly integrate with Bruker's advanced NMR systems, such as the Avance III HD, Avance Neo, and other compatible systems.

The H9877 B-ACS 120 Sample Changer is meticulously crafted to ensure efficient and accurate sample handling. Its robust design features a precision-machined aluminum carousel that rotates smoothly and evenly, minimizing the risk of sample misalignment or damage. This carousel is capable of holding a wide variety of sample tube types, including 5mm, 7mm, and 10mm tubes, making it an incredibly versatile solution for a diverse range of NMR applications.

The sample changer boasts an impressive temperature control system that maintains a consistent temperature for your samples, ensuring optimal experimental conditions. It is also equipped with a high-capacity cooling system that can rapidly chill samples to as low as -50 C, which is particularly useful for experiments involving temperature-sensitive materials.

The intuitive and user-friendly Bruker TopSpin software interface allows for easy control and monitoring of the sample changer. It offers features such as automated sample changing, remote control, and real-time status updates. The software also enables users to program and customize experimental parameters, providing greater flexibility and control over their NMR experiments.

Additionally, the H9877 B-ACS 120 Sample Changer is designed with a modular architecture, making it simple to upgrade and expand as your research needs evolve. This future-proof design ensures that your investment remains a valuable asset in your laboratory for years to come.

Overall, the Bruker H9877 B-ACS 120 Sample Changer is an indispensable tool for any NMR researcher. Its unparalleled sample handling capabilities, temperature control, and user-friendly software interface make it an invaluable addition to your Bruker NMR system, enabling you to perform more experiments with greater efficiency and accuracy.

The Bruker H9877 B-ACS 120 sample changer with a 400US carousel magazine for NMR spectroscopy is a popular accessory for advanced NMR experiments that require the analysis of a large number of samples. Here are some pros and cons of buying this sample changer for your NMR system:

Pros:

1. Increased throughput: With a capacity of 120 samples, this sample changer significantly increases the number of samples that can be analyzed in a single run, saving time and effort.

2. Improved automation: The sample changer automates the process of loading and unloading samples, reducing the risk of errors and improving the overall efficiency of your NMR experiments.

3. Enhanced data quality: By minimizing the time spent on sample preparation and handling, this sample changer can help improve the data quality of your NMR spectra by reducing the effects of sample instability and temperature drift.

4. Flexibility: The carousel magazine design allows for easy configuration of experiments with different sample types and sizes, making it a versatile accessory for a wide range of applications.

Cons:

1. Cost: The Bruker H9877 B-ACS 120 sample changer with a 400US carousel magazine is a significant investment, with a high upfront cost that may be a barrier for some researchers.

2. Complexity: The sample changer adds an additional layer of complexity to your NMR system, requiring additional maintenance and calibration to ensure optimal performance.

3. Size and weight: The sample changer is a large and heavy accessory, requiring additional space and resources to install and operate.

4. Compatibility: This sample changer is specifically designed for use with Bruker NMR systems, and may not be compatible with other brands or models.

Conclusion:

The Bruker H9877 B-ACS 120 sample changer with a 400US carousel magazine offers numerous benefits for researchers who require the analysis of a large number of samples in their NMR experiments. Its increased throughput, improved automation, enhanced data quality, and flexibility make it a valuable investment for advanced NMR research. However, its high cost, complexity, size and weight, and compatibility limitations are important considerations that should be weighed against the benefits before making a purchase.

Recommendation:

If you require the analysis of a large number of samples in your NMR experiments and have the resources to invest in a high-performance sample changer, the Bruker H9877 B-ACS 120 sample changer with a 400US carousel magazine is a strong recommendation. Its advanced features and capabilities can help streamline your workflow, improve data quality, and increase the overall efficiency of your NMR research. However, if the cost or compatibility limitations are a concern, you may want to consider alternative sample changer solutions or prioritize other investments for your research program.

Details:

The sample changer will then either, enter the READY loop and wait for an external command or, when all positions are occupied, interrupt the initialization and display error message No. Idled Product Code #: BRUKER NMR AUTOSAMPLER. Easy set-up procedures are accomplished via dialog software at three user-interface levels. Power Supply Requirements.

The internal logic will then check the puncher status and if no sample is found in puncher, enter READY waiting loop. Manual control of the movement magazine belt is accomplished by pushing two buttons located on side panel the magazine. Air Requirements. Only trained personnel should be allowed to operate B-ACS.

Before Mounting the Automatic Sample Changer. Note: When using the manual control beware of glass tubes moving in front your fingers. If the puncher is holding a sample, the sample changer will try to place it in the actual magazine position x or, if this one occupied, into next empty magazine. Test for Sample in Magnet security test.

Read this manual before operating the unit. Safety Considerations. Make sure the magnet is firmly secured to its base in order to prevent instrumentation from tipping over. Manual Motion Control of the Magazine Belt.

Excessive tension of the magazine belt will damage Beltane wheel bearings. Please refer to B-ACS 120 Sample Changer 400US s://2210pc.chem.uric.educ/nmr/downloads/Bruker/ /PDF/z31597.PDF. During the initialization following message will be shown on LC display: SAMPLE CHANGER. If a sample is present in the magnet, further check Willie performed to see if spinning and/or locked.

Specialized routines assist data interpretation. The push buttons are active only when the sample changer is not busy,i.e. Front Panel Controls. The vertical cylinder up and the puncher on top of the opening at magnet.

Keep all metal objects, such as tools, screws, or any metallic parts away from the magnet. The following notices will have the same level of importance throughout this manual. Through technical defect burst in pneumatic hose. Warning: When the sample changer is in operation keep hands and other objects away from punchers anther end of vertical cylinder.

Service or maintenance work on the unit must be carried out by qualified personnel. On rare occasions it maybe necessary to do a new initialization, if the above mentioned intervention did not correct error. Idling in the ready loop. X or x / x.

To resume operation after the error has been corrected,press CONT button. Potentially Hazardous Areas. It is highly recommended that oxygen warning device be installed in the laboratory. The optional sample warmer see Sample Heater Option located on the magazine belt reaches extreme temperatures: Warning: Do not insert your fingers into the sample.

On the front side of upper column assembly. The sample changer can be started either by pressing the power switch or the RESET button. When assembling the column, do not tighten top fastening ring too hard, as this may cause damage to column surfaces. Operating Instructions.

RESET: A push button for system initialization. When fixing the column to magnet, mount bottom arms that they do not obstruct access when adjusting or changing probes. Beware of the strong magnetic field while working around the magnet. The arm will then move to its stand-by position,.e.

Sample Changer depending on model and options, Fuse Protection. While Mounting the Column. Arrow Selection Buttons: Push buttons for manual magazine motion.

If a failure occurs during operation, the sample changer interrupts current procedure, causing red CONT LED on front paneled flash and off. Please refer to Site Planning for AVANCE Systems 300700 MHz User Guide s://2210pc.chem.uric.educ/nmr/downloads/BASHCD10/PDF/z31276.PDF. Pay particular attention to any safety related information. The standard NMR software includes the comprehensive automation package required for Automatic Sample Changer.

At the end of this test normal sample changing procedure will begin. An error message, consisting of a code number and text,also show up on the display an signal is transmitted to host. Similarly, it is practical to leave a few free spaces between groups, which can be filled up at the last minute, with similar solvent samples. Do not put your finger into the sample warmer.

Ouch Product #: Bruker Advance III HD 400 MHz. The host computer controls various elements of the sample changer through use software commands. When handling tools, screws, or any metallic parts beware of the strong magnetic field. After the initialization, and during READY loop, the following message is displayed: POSITION No.

Item Code #: ITEM-24895 for Bruker Automatic Sample Changer NMR Auto sampler B-ACS 60 Lab Spares/Repairs. Fitting Samples into the Sample Magazine. This allows similar solvents to be grouped in contiguous positions order to speed up the locking procedure. WARNING: Indicates the possibility of severe personal injury, loss life or equipment damage if instructions are not followed.

LC DISPLAY: Used for the current status and error messages. Where x indicates the current position of magazine. Specifications. At the End of Operation.

Glass tubes may contain hazardous substances. Alternatively, nitrogen may be used. Remove any mechanical watches or metallic objects while working around the magnet. Gaps of one or more empty spaces are allowed between samples.

CONT: A push button for continuation after a failure occurs. The use of nitrogen as an operating resource instead of compressed air may lead to oxygen deficiency in the laboratory, condition: Use din Clean, Excellent working condition. It features automatic instrument optimization, phasing, integration and plotting.

The air source must be clean, dry, and oil-free. Only those persons schooled in the operation of B-ACS should operate unit. On the upper left half of front side that is away from magnet vertical cylinder. Site Considerations.

Turning off the B-ACS may cause a short motion of the horizontal cylinder due to opening all valves. When the Automatic Sample Changer is running, avoid putting hands or objects in path of arm, magazine belt puncher, as this Marcuse personal injury damage to equipment. The sample changer can then be started through use of the power switch. If a glass tube breaks, refer to the corresponding precautions and cleaning/disinfection instructions.

The symbol is placed on the following areas of Automatic Sample Changer. The Occurrence of a Failure. There are two types of information notices used in this manual. During this procedure the sample changer will automatically look for next to be handled.

part #: h9877 price

  • $1495.00

specifications labequipi:

  • brand: Bruker
  • mpn: H9877
  • part type: Ac Changer
  • country/region of manufacture: Germany
  • intended use/discipline: Biological Laboratory, Medical Laboratory, Microbiological Laboratory

payments labequipi:

  • other
  • credit card: Diners-club
  • wallet: Google-pay

offer labequipi:

  • availability: In Stock
  • options: Ship-to-home
  • best offers: True
  • sold: 0
  • quantity: 1
  • started: March 30, 2025

seller labequipi:

  • rating: 97.0%
  • # reviews: 3884
  • city: Huntington Beach, California

returns labequipi:

  • paid by: Buyer
  • policy: Returns Accepted
  • method: Money back
  • time: 30 Days

shipping labequipi:

  • service: Flat Rate Freight
  • cost: $295.00
  • class: Freight
  • type: Fixed

general labequipi:

  • Healthcare, Lab Dental > Medical Lab Equipment, Devices > Other Medical Lab Equipment
  • condition: Used
part type: ac changer, country/region of manufacture: germany, intended use/discipline: biological laboratory, medical laboratory, microbiological laboratory,
category: business & industrial > healthcare, lab dental > medical lab equipment, devices > medical lab equipment, sku: 16482458095276622,
Bruker H9877 Is Similar To:
  • (27.3% similar) This item was recently removed from service by a major USA dharma manufacturer. Only comes with what is shown in the photos. Sold as pictured. Bruker Z105909 3.0MM USCG nmr shuttle for sample jet - ECL05.01,: to hold sample tubes for automated loader system. Condition: used. Test results of item are...(July 1st, 2025)
  • (36.5% similar) The unit and connectors are in good condition. Ships securely in custom eds-safe packaging. This Bruker dry e AWS ECL02 Z102520 dry-e for MRI nmr was removed from a working system but has not been bench tested...(July 18th, 2025)
  • (27.3% similar) Condition: used. Great physical condition. Bruker Z105515 5.0MM USCG nmr shuttle for sample jet - ECL05.01,: to hold sample tubes for automated loader system. What you see in the picture is/are what get, nothing more less. Sold as pictured. Only comes with what is shown in the photos. This item was ...(October 14th, 2025)
  • (28.8% similar) Great physical condition. This item was recently removed from service by a major USA dharma manufacturer. Test results of item are described to the best our ability in listing. What you see in the picture is/are what get, nothing more less. Sold as pictured. Condition: used. Bruker Z106558 1.7MM ...(October 14th, 2025)
  • (25.9% similar) Used - powers up, no further testing done. See pictures for more details. Caliper life science variant Bruker Sims nmr auto sampler 47614 47614/12...(March 17th, 2026)
labequipi logo
1 offer $1495.00 USD
  • Used. Offer #1 priced at $1495.00 + $295.00 shipping estimate = $1790.00* total. Easy set-up procedures are accomplished via dialog software at three user-interface levels Specialized routines assist data interpretation.+$295.00 shipping

Copyright © labequipi.com