( Brand: Microfluidics ), ( Manufacturer Part Number: M110P ), ( Model: M-110P ), ( Part Type: Hydraulic Homogenizer ), ( Intended Use/discipline: Biological Laboratory, Medical Laboratory, Microbiological Laboratory )
The M110P/M-110P Electric-Hydraulic Microfluidizer Processor Homogenizer by Microfluidics is a versatile and powerful laboratory instrument designed for the production of uniform dispersions and fine emulsions. This microfluidizer processor homogenizer is an essential tool for researchers and scientists in various industries such as pharmaceuticals, food and beverage, and materials science.
The M110P/M-110P features an electric-hydraulic pump system that provides consistent and precise pressure control, ranging from 0 to 30,000 psi (0 to 2,070 bar). This wide pressure range enables the processing of a broad range of viscosities, from water to high-viscosity samples. The system's high shear and turbulent flow conditions result in the smallest droplet sizes and most uniform dispersions possible.
The microfluidizer processor homogenizer consists of a stainless steel housing for durability and easy cleaning. The M110P model includes a touchscreen control panel, while the M-110P model features a manual operation with pressure gauge and pressure relief valve. Both models offer easy and quick sample processing, with processing volumes ranging from 2 ml to 120 liters.
The microfluidizer technology used in the M110P/M-110P homogenizer offers several advantages over traditional methods, such as reduced processing time, lower energy consumption, and the ability to process heat-sensitive samples without the need for heating or cooling. Additionally, the system's closed system design ensures sample containment and minimizes contamination risks.
The M110P/M-110P microfluidizer processor homogenizer comes with a range of processing accessories, including various size microfluidizer processors, adaptors for different sample container sizes, and a recirculation loop for continuous processing. The system is easy to maintain, with replaceable wear parts and a user-friendly design for easy cleaning and setup.
In summary, the M110P/M-110P Electric-Hydraulic Microfluidizer Processor Homogenizer by Microfluidics is an advanced and versatile laboratory instrument for the production of uniform dispersions and fine emulsions. Its consistent pressure control, wide pressure range, and microfluidizer technology offer several advantages over traditional methods, making it an indispensable tool for researchers and scientists in various industries.
The Microfluidics M110P and M-110P electric-hydraulic microfluidizer processors are high-performance homogenizers widely used in various industries, including pharmaceuticals, food, and beverages, for emulsifying, dispersing, and processing liquids. This analysis explores the pros and cons of investing in this microfluidizer to help potential buyers make an informed decision.
Pros:1. Versatility: The M110P and M-110P microfluidizers are suitable for a wide range of applications, from producing nanoemulsions and microemulsions to dispersing solid particles and processing viscous samples.
2. Consistent Results: These microfluidizers provide consistent and reliable results due to their precise and controllable process conditions.
3. High Shear Rate: The high shear rates achieved during the homogenization process ensure efficient particle size reduction and optimal dispersion of solids in liquids.
4. Easy to Clean: The design of these microfluidizers facilitates easy cleaning and maintenance, which is essential in industries where product purity is crucial.
5. Scalability: The M110P and M-110P microfluidizers are available in various sizes, allowing users to choose the appropriate model based on their production requirements.
Cons:1. High Initial Investment: The cost of purchasing a microfluidizer can be substantial, which might be a deterrent for small-scale or budget-conscious businesses.
2. Complex Operation: Operating a microfluidizer requires a certain level of expertise and attention, and incorrect usage could potentially damage the equipment or yield inconsistent results.
3. Limited Sample Volume: The microfluidizer can only process a limited volume of sample at a time, which might necessitate continuous processing for larger batches.
Conclusion:The Microfluidics M110P and M-110P electric-hydraulic microfluidizer processors offer numerous benefits, including versatility, consistent results, high shear rates, easy cleaning, and scalability. However, they come with a high initial investment, complex operation, and limited sample volume. If the advantages outweigh the disadvantages for your specific application and budget, this microfluidizer could be an excellent investment for your business.
Recommendation:If you are considering purchasing a microfluidizer for your business, carefully evaluate your application requirements, budget, and production scale. If your process demands high precision, consistent results, and efficient particle size reduction, the M110P and M-110P microfluidizers from Microfluidics could be an excellent choice. However, if your budget is limited or your production scale is small, you might consider alternative homogenization technologies or smaller-scale microfluidizers. Always consult with industry experts and equipment suppliers to ensure you make the best decision for your business.
After its initial disinfection and inspection, our technicians tested the Microfluidics M-110P electric-hydraulic bench top microfluidizer processor with following results. Cleaned and inspected liquid end: PASSED, - Ran sterilized with 2 liters of improperly alcohol: Verify maximum operating pressure 30,000 psi: Check process control valve: motor start/stop control: Check/replace plunger seal assembly: Clean inspect plunger: bearing isolate/o-rings: high fittings: inlet check inspect/replace priming hydraulic oil filter: the reservoir: suction strainer: Inspect/replace cylinder seals: Back flush interaction chamber: PASSED. Minimum sample size. Microfluidics M-110P Electric-Hydraulic High-Shear Bench top Microfluidizer Processor 110V, - G10Z 87 Micron Ceramic Interaction Chamber IXC, Vertical Cooling Bath, Large Stainless Steel Reservoir, 400 ml Preventative Maintenance Toolkit, Power Cable with NEMA 5-15P Plug, 90-Day Warranty.
I could not be happier with the piece of equipment that was able to get through New Life. Because we placed an order through New Life Scientific for a used Loopholes, were able to get that super fast, so could move forward. Up to 30,000 psi 2068 bar. I wouldn't say had bad experiences, BUT only good experiences with New Life Scientific.
Product temperature limit. Manufacturer. Power rating. I looked at a few local refurbishing companies.
Dimensions W HX. They are very responsive, especially Micah. I feel very lucky. They really make me feel like an important customer.
Quality, Inspection: Our instruments are inspected, tested, repaired, serviced and supported by our technicians. Specifications. Notice: Please review the technician checklist in product images to see more details of inspection and testing performed. Fully Tested and Working Without Issue.