( Brand: Medtronic ), ( Manufacturer Part Number: T7660 ), ( Part Type: Ring )
The Medtronic T7660 Duran Anorexia Ring/Band Annuloplasty device is a surgical implant designed to repair and reinforce the annulus fibrosus, the fibrous ring that supports the nucleus pulposus in the spinal disc. This device is specifically indicated for use in the thoracic and lumbar regions of the spine to treat patients suffering from annular tears or ruptures, which can lead to chronic back pain and disability.
The T7660 Duran Anorexia Ring is made of a biocompatible, expanded polytetrafluoroethylene (ePTFE) material that is known for its excellent tissue compatibility and low risk of complications. The ring is available in various sizes and shapes to accommodate the unique anatomy of each patient's spine.
During the surgical procedure, the damaged annulus fibrosus is carefully removed, and the T7660 Duran Anorexia Ring is inserted into the annular defect. The ring is designed to be self-expanding, allowing it to conform to the shape of the annulus and provide uniform compression. The compression helps to restore the height and integrity of the affected disc, reducing the pressure on the surrounding nerves and relieving pain.
The T7660 Duran Anorexia Ring also features a unique, anchoring system that secures the device in place. The system consists of a series of small, anchoring hooks that are attached to the ring and designed to engage the adjacent vertebral endplates. This anchoring system helps to prevent the ring from migrating or shifting position after implantation, ensuring long-term stability and effectiveness.
Overall, the Medtronic T7660 Duran Anorexia Ring/Band Annuloplasty is a highly effective and innovative solution for the treatment of annular tears and ruptures in the thoracic and lumbar regions of the spine. Its biocompatible material, self-expanding design, and secure anchoring system make it a safe and reliable option for patients seeking relief from chronic back pain.
Medtronic T7660 Duran Annuloplasty Ring/Band is a surgical device used in annuloplasty procedures to repair the mitral valve in the heart. Annuloplasty is a type of heart valve surgery that reinforces and reshapes the annulus, or ring, around the heart valve to help it function properly. Here are some pros and cons of buying a Medtronic T7660 Duran Annuloplasty Ring/Band:
Pros:1. High-quality material: The Medtronic T7660 Duran Annuloplasty Ring/Band is made of durable, biocompatible material that is resistant to infection and can withstand the demands of the cardiovascular system.
2. Adjustable size: The ring comes in various sizes and can be adjusted during the surgery to ensure a proper fit, which is crucial for effective valve repair.
3. Proven track record: The Medtronic Duran Annuloplasty Ring has been used in thousands of successful heart valve repairs, making it a trusted and reliable option for medical professionals.
4. Reduced risk of complications: The use of annuloplasty rings, such as the Medtronic T7660 Duran Ring, can help reduce the risk of complications, such as valve regurgitation, compared to other surgical methods.
Cons:1. High cost: The Medtronic T7660 Duran Annuloplasty Ring/Band is a costly device, and the overall cost of using it in a surgical procedure can be significant.
2. Requires surgical expertise: The use of annuloplasty rings, including the Medtronic T7660 Duran Ring, requires a high level of surgical expertise and experience. The procedure is complex and carries risks, such as bleeding, infection, and damage to surrounding tissues.
3. Long recovery time: Heart valve surgery, including annuloplasty procedures using the Medtronic T7660 Duran Annuloplasty Ring/Band, can require a lengthy recovery time. Patients may need to stay in the hospital for several days and undergo rehabilitation before returning to their normal activities.
In conclusion, the Medtronic T7660 Duran Annuloplasty Ring/Band is a high-quality, durable device that can effectively repair the mitral valve in the heart. However, it comes with a high cost and requires a high level of surgical expertise and a lengthy recovery time. Ultimately, the decision to use the Medtronic T7660 Duran Annuloplasty Ring/Band should be made in consultation with a medical professional based on the individual patient's needs and circumstances.
Recommendation: If you or a loved one requires heart valve repair and your medical professional recommends the use of the Medtronic T7660 Duran Annuloplasty Ring/Band, it is important to understand the risks and benefits of the procedure and the role of the device in the surgery. Make sure to discuss any concerns with your medical team and follow their recommendations for care and recovery.
Regardless of the origin equipment, documentation provided or identification appearing upon equipment described and offered here is in no way certified for, recommended for any specific use. For all others, there might extra. Inventory ID: WH2-Z2-S6A, 070325, BAE. Comes as pictured.
1841 W Carriage House Dr, Baton Rouge, LA 70815. We acquired the unit in a state surplus sale. Please see the pictures for cosmetic condition.
No other accessories. Shipping Handling.