LONZA V4SP-3960 Pack Amaxa Cell Nucleofector Kit Nucleocuvette 96-WELL

V4sp-3960 Lonza Pack Of 10 Amaxa P3 Primary Cell 96-well Nucleofector Kit With Warranty

( Brand: Lonza ), ( Manufacturer Part Number: V4SP-3960 ), ( Model: NUCLEOCUVETTE ), ( Part Type: Cell )

Review LONZA Pack Of Amaxa P3 Primary Cell 96-well Nucleofector Kit Warranty

The Lonza AMAXA P3 Primary Cell 96-Well Nucleofector Kit (Catalog No. V4SP-3960, Pack Size: 10) is a comprehensive and efficient solution for nucleofection of primary cells in a high-throughput format. This kit is designed for researchers working with adherent or suspension primary cells, including but not limited to T-cells, B-cells, NK-cells, epithelial cells, fibroblasts, and neuronal cells.

The kit includes ten (10) complete Nucleofector II Devices, each capable of processing up to 96 samples in a 96-well format. The Nucleofector II Device utilizes optimized electroporation conditions for a wide range of primary cell types, ensuring high transfection efficiency and minimal cell damage.

The kit also provides ten (10) sets of Nucleofector Solution V, which is specifically formulated for primary cells. This solution contains a proprietary buffer system that optimizes the electroporation conditions for these delicate cells, enhancing their viability and transfection efficiency.

Additionally, the kit includes ten (10) sets of Nucleofector Accessory Kit A, which contains all the necessary components for nucleofection in a 96-well format, including the Nucleofector Capacitance-Coupled Electrodes, the Nucleofector Adapter Plate, and the Nucleofector 96-Well Plate.

The AMAXA P3 Primary Cell 96-Well Nucleofector Kit offers several advantages over traditional transfection methods. Its high-throughput format allows for large-scale experiments, reducing the time and effort required for transfection. Moreover, the gentle electroporation process minimizes cell damage and maintains cell viability, making it an ideal method for working with primary cells.

In summary, the Lonza AMAXA P3 Primary Cell 96-Well Nucleofector Kit (Catalog No. V4SP-3960, Pack Size: 10) is a versatile and efficient solution for nucleofection of primary cells in a high-throughput format. It includes ten (10) complete Nucleofector II Devices, ten (10) sets of Nucleofector Solution V, and ten (10) sets of Nucleofector Accessory Kit A, enabling researchers to process up to 96 primary cell samples simultaneously. With its optimized electroporation conditions and minimal cell damage, this kit is an essential tool for any researcher working with primary cells.

A Comprehensive Analysis of Lonza V4SP-3960 Pack 10 AMAXA P3 Cell 96-Well Nucleofector Kit

Introduction:

The Lonza V4SP-3960 Pack 10 AMAXA P3 Cell 96-Well Nucleofector Kit is a popular choice for large-scale nucleofection experiments. This equipment is used to transfer genomic material into cells, enabling gene transfection. In this analysis, we will discuss the pros and cons of investing in this kit, and provide a concluding recommendation.

Pros:

1. High-throughput: This kit allows for the nucleofection of 96 samples simultaneously, making it an excellent choice for large-scale experiments or screens.

2. Improved transfection efficiency: The P3 system provides enhanced transfection efficiency compared to traditional methods, ensuring successful gene transfer.

3. Versatile: The kit is suitable for various cell types, including mammalian, primary, and plant cells, making it a versatile tool for researchers.

4. User-friendly: The kit includes detailed instructions, making it accessible for researchers with minimal experience in nucleofection.

5. Consistent results: The use of this automated system increases the reproducibility of results, reducing the variability typically associated with manual nucleofection techniques.

Cons:

1. Cost: The high cost of the kit may be a barrier for some researchers, particularly those working on tight budgets.

2. Limited capacity: While the 96-well format is advantageous for high-throughput experiments, it may not be suitable for smaller experiments or those requiring a larger volume of nucleofection solution.

3. Maintenance: The automated system requires regular maintenance to ensure optimal performance, which can be time-consuming and costly.

4. Complexity: The use of automated equipment may require additional training for researchers, potentially increasing the time and resources needed to get started.

Conclusion:

The Lonza V4SP-3960 Pack 10 AMAXA P3 Cell 96-Well Nucleofector Kit offers several benefits for researchers, including high-throughput, improved transfection efficiency, versatility, and user-friendliness. However, the high cost, limited capacity, maintenance requirements, and complexity may be drawbacks for some.

Recommendation:

If you are conducting large-scale nucleofection experiments, require consistent results, and have the necessary budget, the Lonza V4SP-3960 Pack 10 AMAXA P3 Cell 96-Well Nucleofector Kit is an excellent investment. However, if you have limited resources, require a smaller capacity, or prefer a more manual approach, alternative nucleofection methods or kits may be more suitable for your needs.

Details:

Please review all photos and details before purchasing. Have a question. 30-Day Return Warranty, Shipping and Handling. Reach out anytime.

part #: v4sp3960 prices

  • $1999.96-$14000.00

specifications labequipi:

  • brand: Lonza
  • mpn: V4sp-3960
  • model: Nucleocuvette
  • part type: Cell

shipping labequipi:

  • cost: $0.00
  • service: Standard
  • class: Standard
  • type: Fixed
  • transit: 5-8 Days

seller labequipi:

  • # reviews: 2464
  • city: Rocklin, California
  • rating: 99.8%

general labequipi:

  • Healthcare, Lab Dental > Medical Lab Equipment, Devices > Other Medical Lab Equipment
  • condition: New

payments labequipi:

  • wallet: Apple-pay
  • credit card: Visa
  • other

offer labequipi:

  • availability: In Stock
  • started: November 26, 2025
  • sold: 0
  • best offers: True
  • options: Ship-to-home
  • quantity: 1

returns labequipi:

  • method: Money back
  • paid by: Seller
  • policy: Returns Accepted
  • time: 30 Days
part type: cell,
category: business & industrial > healthcare, lab dental > medical lab equipment, devices > medical lab equipment, sku: 21808300148401722,
Lonza V4SP-3960 Is Similar To:
  • (38.7% similar) 100.00 dollars for shipping in the USA 48 lower states. This unit comes as pictured. It is been under storage for a while, I am sorry don't know what did with the power supply 96 well shuttle. Everything works please see pictures or ask a question...(August 9th, 2024)
  • (42% similar) For closed, salable large-scale transduction of up to 1X10 9 cells. Lonza 4d nucleofector lav unit AAF-1002L. If you require expedited shipping or wish to be billed your FedEx ups DHL account# please let us know upon purchase. 2025 blabbed. Brand new unit...(March 21st, 2025)
labequipi logo
5 offers $1999.96–$14000.00 USD
  • Used. Offer #1 priced at $14000.00 + $750.00 shipping estimate = $14750.00* total. The LV Unit allows for closed, scalable transfection of larger cell numbers in the range of 1x107 to 1x109 cells Lonza LV Unit.+$750.00 shipping
  • Used. Offer #2 priced at $1999.96 + $0.00 shipping estimate = $1999.96* total. Power Source: Via connection to Core Unit (no separate power input). Technology: Nucleofection direct transfer of DNA/RNA/proteins into the nucleus.FREE SHIPPING
  • Used. Offer #3 priced at $2520.00 + $24.75 shipping estimate = $2544.75* total. Model: Nucleofector II + 96-Well Shuttle. For cell lines, five different Nucleofector Solutions (C, L, R, T and V) are available.+$24.75 shipping
  • Used. Offer #4 priced at $4274.50 + $48.21 shipping estimate = $4322.71* total. location. - Lonza 4D-Nucleofector Core Unit.+$48.21 shipping
  • Used. Offer #5 priced at $4274.50 + $48.21 shipping estimate = $4322.71* total. +$48.21 shipping

Copyright © labequipi.com